All Issue

2015 Vol.57, Issue 5 Preview Page
2015. pp. 51–60
Abstract
In Korea, 69.4 % of duck farms had utilized conventional plastic greenhouses. In this facilities, there are difficulties in controlling indoor environments for raising duck. High rearing density in duct farms also made the environmental control difficult resulting in getting more stressed making their immune system weaker. Therefore, a facility is needed to having structurally enough solidity and high efficiency on the environmental control. So, new design plans of duck house have recently been conducted by National Institute of Animal Science in Korea. As a study in advance to establish standard, computational fluid dynamics (CFD) was used to estimate the aerodynamic problems according to the designs by means of overall and regional ventilation efficiencies quantitatively and qualitatively. Tracer gas decay (TGD) method was used to calculate ventilation rate according to the structural characteristics of duck houses including installation of indoor circulation fan. The results showed that natural ventilation rate was averagely 164 % higher than typically designed ventilation rate, 1 AER (min -1 ). Meanwhile, mechanically ventilated duck houses made 81.2 % of summer ventilation rate requirement. Therefore, it is urgent to develop a new duck house considering more structural safety as well as higher efficiency of environmental control.
References
Sorry, not available.
Click the PDF button.
Information
  • Publisher :The Korean Society of Agricultural Engineers
  • Publisher(Ko) :한국농공학회
  • Journal Title :Journal of Korean Society of Agricultural Engineers
  • Journal Title(Ko) :한국농공학회논문집
  • Volume : 57
  • No :5
  • Pages :51–60