Abstract
References
Sorry, not available.
Click the PDF button.
Information
The objective of this study is to find the electrical properties of Bottom ash from thermoelectric power plants in Korea. By using Parallel Plate Method, the electrical resistivity and dielectric constant were measured at the frequency from 20 Hz to 10 MHz. Also, unconfined strength test, XRF and sieve analysis were performed for finding the relationship between strength, physiochemical properties and electrical properties. In the result, the change of electrical resistivity and dielectric constant of bottom ash against frequency was similar to that of general soil. The proportion of fine grain in bottom ash had the positive correlation with dielectric constant and negative correlation with electrical resistivity. Chloride and sulfur trioxide were proportional to dielectric constant and the more bottom ash had chloride content, the lower electrical resistivity appeared in bottom ash. Unconfined strength of bottom ashes had a range from 200 kPa to 780 kPa and strength was inverse proportional to electrical resistivity.
Click the PDF button.
- Publisher :The Korean Society of Agricultural Engineers
- Publisher(Ko) :한국농공학회
- Journal Title :Journal of Korean Society of Agricultural Engineers
- Journal Title(Ko) :한국농공학회논문집
- Volume : 56
- No :1
- Pages :21–30


Journal of Korean Society of Agricultural Engineers