All Issue

2019 Vol.61, Issue 2 Preview Page
2019. pp. 85–95
Abstract
The internal environment in pig house is closely related to the animal productivity. In addition, it is important to consider a working environment inside the pig house due to high gas and dust concentrations. The poor working environment inside the pig house can cause health problems including respiratory diseases. To analyze the working environment, it is important to evaluate the ventilation efficiency to effectively remove harmful gases and dust. The purpose of this study is to develop a 3D CFD model to analyze the working environment in the pig house. CFD model was validated by comparing air temperature distributions between CFD computed and field measured data. The average air flow rate at the pig height was 40.1 % lower than the working height when incoming air was concentrated on upper layer by the installed ventilation system on the experimental pig house. Using the validated CFD model, the regional ventilation efficiency was computed by the TGD(tracer gas decay) method at the pig and working heights. There was a difference of ventilation efficiency on 14 % between the air stagnated section and the rest sections. Stagnated gas concentration can be effected by animal and human health.
References
Sorry, not available.
Click the PDF button.
Information
  • Publisher :The Korean Society of Agricultural Engineers
  • Publisher(Ko) :한국농공학회
  • Journal Title :Journal of Korean Society of Agricultural Engineers
  • Journal Title(Ko) :한국농공학회논문집
  • Volume : 61
  • No :2
  • Pages :85–95