All Issue

2026 Vol.68, Issue 2 Preview Page
2026. pp. 55-64
Abstract
References

REFERENCES

1
R. B. Brinkgreve, M. Bürg, A. Andreykiv and L. J. Lim, In Proc. workshop ‘Numerische Methoden in der Geotechnik’. BundesAnstalt für Wasserbau, Karlsruhe, Beyond the finite element method in geotechnical analysis, 98; 91-102 (2015)
2
F. F. Chimdesa, F. F. Chimdesa, N. Z. Jilo, A. Hulagabali, O. E. Babalola, T. Tiyasha, K. Ramaswamy, A. Kumar and S. K. Bhagat, Scientific Reports, Numerical analysis of pile group, piled raft, and footing using finite element software PLAXIS 2D and GEO5, 13(1); 15875 (2023)10.1038/s41598-023-42783-x
3
M. K. Choi, S. W. Yun, H. N. Kim, S. Y. Lee, C. Yu and Y. C. Yoon, Protected Horticulture and Plant Factory, Uplift capacity of pipe foundation for single-span greenhouse, 24(2); 69-78, (in Korean) (2015)10.12791/ksbec.2015.24.2.069
4
European Committee for Standardization (CEN), EN 13031-1 : Greenhouses - Design and construction - Part 1: Commercial production greenhouses (2019)
5
D. Hao, Y. Zhang, Y. Chen, R. Chen, G. Kong, K. Wu and Y. Han, Scientific Reports, Numerical analysis of bearing capacity of winged helical anchor in clayed soil, 15; 16380 (2025)10.1038/s41598-025-00571-9
6
M. S. Islam, G. Sarkar, M. R. Tajnin, M. Rokonuzzaman and T. Sakai, Ocean Engineering, Limit load of strip anchors in uniform cohesive-frictional soil, 190; 106428 (2019)10.1016/j.oceaneng.2019.106428
7
Japan Greenhouse Horticulture Association, Tokyo, Japan Greenhouse Horticulture Association, Standard for structural safety of greenhouse, (in Japanese) (1997)
8
M. K. Kim and S. W. Nam, Journal of Bio-Environmental Control, Experimental studies on the structural safety of pipe-house, 4(1); 17-24, (in Korean) (1995)
9
M. S. Kim, K. S. Choi and H. J. Lee, Journal of the Regional Association of Architectural Institute of Korea, Uplift and lateral capacity of strip pipe foundation for single-span greenhouse depend on field compacting conditions, 19(6); 113-120 (2017)
10
Korea Expressway Corporation, Road Design Guidelines, Vol. 2, (in Korean) (2020)
11
S. I. Lee, Y. J. Jeong, J. H. Lee, G. Chung and W. Choi, Biosystems Engineering, Development of a heavy snowfall alarm model using a Markov chain for disaster prevention to greenhouses, 200; 353-365 (2020)10.1016/j.biosystemseng.2020.10.019
12
S. Lee, J. H. Lee, B. H. Seo, D. S. Kim, D. Kim, Y. Jo and W. Choi, Biosystems Engineering, Stiffness evaluation of semi-rigid connection using steel clamps in plastic greenhouse structure, 250; 15-27 (2025a)10.1016/j.biosystemseng.2024.11.018
13
W. Y. Lee, Y. H. Son, S. B. Jo, J. H. Jeon and T. J. Kim, Journal of the Korean Society of Agricultural Engineers, Development of a theoretical equation for ultimate uplift capacity of disaster-resistant greenhouse continuous pipe foundation through model tests, 67(3); 71-83, (in Korean) (2025b)10.5389/KSAE.2025.67.3.071
14
Ministry of Agriculture, Food and Rural Affairs, Greenhouse status for greenhouse vegetable, (in Korean) (2025)
15
Ministry of Agriculture, Food and Rural Affairs and Rural Development Administration, Designated notice of standards to endure disaster for horticultural and special facilities, Korea (2025)
16
M. S. Nam, S. I. Kim, S. W. Hong, S. C. Hwang and Y. K. Choi, Journal of the Korean Geoenvironmental Society, A numerical analysis study for estimation of ultimate bearing capacity and an analysis of the high capacity bi-directional pile load tests of the large-diameter drilled shafts, 12(10); 63-72, (in Korean) (2011)10.14481/jkges.2011.12.10.8
17
National Greenhouse Manufactures Association (NGMA), Structural Design Manual, NGMA, PA, USA. (2004)
18
G. Russo, International Journal for Numerical and Analytical Methods in Geomechanics, Numerical analysis of piled rafts, 22(6); 477-493 (1998)10.1002/(sici)1096-9853(199806)22:6<477::aid-nag931>3.0.co;2-h
19
M. Sadek and I. Shahrour, International journal for numerical and analytical methods in geomechanics, A three dimensional embedded beam element for reinforced geomaterials, 28(9); 931-946 (2004)10.1002/nag.357
20
B. H. Seo, S. I. Lee, J. H. Lee, D. S. Kim, D. W. Kim, Y. R. Jo, Y. Y. Kim, J. M. Lee and W. Choi, Journal of the Korean Society of Agricultural Engineers, Structural shape estimation based on 3D LiDAR scanning method for on-site safety diagnostic of plastic greenhouse, 66(5); 1-13, (in Korean) (2024)10.5389/KSAE.2024.66.5.001
21
A. Truty, Engineering Structures, Nonlocal FEM modeling of piles as beam elements embedded within 3D continuum, 277; 115460 (2023)10.1016/j.engstruct.2022.115460
22
S. W. Yun, M. K. Choi, S. Y. Lee, D. H. Kang, S. D. Moon, C. Yu and Y. C. Yoon, Protected Horticulture and Plant Factory, Uplift capacity of shallow foundation for greenhouse, 24(3); 187-195, (in Korean) (2015)10.12791/ksbec.2015.24.3.187
23
S. W. Yun, M. K. Choi, C. Yu and Y. C. Yun, In Proc. Korean Society of Agricultural Engineers Conference, Evaluation of loads acting on greenhouse foundation considering wind and snow load, 2013; 120 (2013)
Information
  • Publisher :The Korean Society of Agricultural Engineers
  • Publisher(Ko) :한국농공학회
  • Journal Title :Journal of Korean Society of Agricultural Engineers
  • Journal Title(Ko) :한국농공학회논문집
  • Volume : 68
  • No :2
  • Pages :55-64
  • Received Date : 2025-10-21
  • Revised Date : 2026-01-09
  • Accepted Date : 2026-01-13